-40%
CD63L Battery Charging Control Module Full Power-off DC Voltage Protector 30A
$ 4.04
- Description
- Size Guide
Description
Product OverviewCD63L Battery Charging Control Module Full Power-off DC Voltage Protector 30A
UP button: Short press to switch display% and time, long press for 5 seconds to switch mode, charging mode: IN, discharging mode: OUT
Charging mode IN
By setting the upper limit voltage UP and the lower limit voltage dn; when the battery voltage ≤ the lower limit voltage dn, the relay is turned on, and the charger starts to charge the battery; when the battery voltage ≥ the upper limit voltage UP, the relay is disconnected to complete an automatic charging; the relay is turned on, IN flashes, indicating that it is charging.
Discharge mode OUT
By setting the upper limit voltage UP and the lower limit voltage dn; when the battery voltage ≥ the upper limit voltage UP, the relay is turned on and starts to discharge; when the battery voltage ≤ the lower limit voltage dn, the relay is disconnected to complete an automatic discharge function; the relay is turned on and OUT flashes, Indicates that it is discharging.
Note: This product is a simple voltage controller, which uses a relay to turn on and off the output. It only functions as a switch and cannot be transformed.
Function Description:
1. Calculation of voltage percentage: battery voltage/(upper limit voltage-lower limit voltage)
2. Key function:
UP button: Short press to switch display% and time, long press for 5 seconds to switch mode, charging mode: IN, discharging mode: OUT
SET button: short press to view the currently set parameters; long press SET button to enter the parameter setting interface, set UP: voltage upper limit, dn: voltage lower limit, OP: conduction time, dOP: delay conduction time (0-999 seconds) , There is FOP in discharge mode: forced conduction time (0-10 seconds)
DOWN button: Short press to turn off/on the relay enable (emergency stop function) after it is turned off, the LCD display is OFF, and the relay is disconnected
Long press the DOWN button to set the status of the LCD backlight. L-P: OFF, the backlight is always on, ON: the backlight will automatically go out after 5-10 minutes; any key to wake up after it goes out.
3. Parameter setting
A. Long press the SET key to enter the parameter setting interface;
B. After entering the parameter setting interface, short press the SET key to switch the set parameters;
C. After selecting the parameter, you can set it through the UP/DOWN key, and support short press and long press;
D. If you want to set other parameters, repeat steps b) and c);
E. After all parameter settings are completed, long press the SET button to exit and save;
3.1 Charge/discharge time control function
When the set time parameter OP is non-zero, start the charge/discharge time control; when the relay is turned on and open for a charge/discharge, start timing; when the timing is completed, the relay is automatically disconnected to complete a charge/discharge process; if the timing is completed, charge In mode, detection voltage
When the charge/discharge time control is not turned on, the product will record the complete time once. When entering the time display interface, the charging time flashes; it will be cleared when it exits the time display interface or the next time the charge is turned on (relay is turned on);
3.2 Automatic parameter detection:
After setting the parameters and exiting, if the lower voltage limit dn ≥ the upper limit voltage up, the system will flash "ERR" to remind you;
3.3 Delayed conduction function dOP (0~999 seconds):
The interval between charging/discharging once and turning on again;
3.4 Discharge conduction forced start time FOP (0~10S):
After the relay conduction conditions are met, the relay is forced to conduct (0~10S), and the battery voltage is detected again; this function is mainly for the discharge function, and some test loads will be instantly pulled down to the lower limit voltage at the moment of conduction, causing false triggering The relay is disconnected and the normal discharge process cannot be carried out;
Common failure analysis:
Question:
How much V level is suitable for use? How much V voltage is suitable for this product?
Answer:
This model is suitable for use in the voltage range of the lowest 6V and the highest 60V, and the maximum expenditure level is 48V, because the 48V battery is fully charged at about 60V, and the higher it is, it will burn. If your battery is higher than 48V, please choose other models.
Question:
The relay pops after power-on!
Answer:
This is because your charging current is too large or the battery capacity is too small. The upper voltage limit is reached immediately after power-on. The relay is disconnected. After disconnection, the voltage drops rapidly to the lower voltage limit, and the charging starts again, and the cycle is repeated. When you need to reduce the charging current, usually the charging current is 1 to 1.5 of the battery capacity, such as 20AH battery charging current is generally around 2-3A! Note that high-current charging will cause the battery to heat up, accelerate aging, bulge or even explode!
Q:
What control method? Can it be recharged automatically? Can I charge while using it? Can it limit the current?
Answer:
This is voltage control. For example, set the lower limit of voltage to 12.0V and upper limit of voltage to 14.5V. When the voltage is charged to 14.5V, the power will be cut off, and the voltage will be reduced to 12.0V. The relay will close and start charging; you can charge while using, and control the voltage. The method only functions to turn off and turn on, and cannot limit the current. The charging current depends entirely on your charger!
Question:
Can the 24V battery be charged by inputting 12V, or can the 12V battery be charged by inputting 48V?
Answer:
This model is a simple voltage controller, which only functions as a switch and cannot change the voltage to charge the battery, so you must prepare what kind of charger you want to charge the battery! necessary!
Shipping Policy
Item Location
Payment Mathord
Returns Policy
About Feedback
Shipping Policy
1. We Ship to Worldwide
2. We ship your orders within 1-2 business days after the payment cleared.
3. Item shipped from China via china Post Airmail, reach most of the countries within 2 to 4 weeks.
4. Delivery time depends on destination and other factors, it may takes up to 20 days. If you don't receive
the item after 30 days,please keep in touch with us, we'll investigate and solve the delivery problem.
5. Import duties, taxes, and charges are not included in the item price or shipping cost. These charges
are the buyer's responsibility. Please check with your country's customs office to determine what these
additional costs will be prior to bidding or buying.
Item Location
ShenZhen
Payment Mathord
1. We accept PAYPAL only.
2. Payment must be made within 7 days of auction closing (Unpaid dispute will automatically open when item
is not paid in 7 days).
3. PLEASE NOTE: SHIPPING&HANDING DOES NOT INCLUDE DUTIES, LOCATL TAXES OR ANY OTHER IMPORTATION FEES.
4. Please list your special requests (color, packages, value of declaration, etc.) in the EBAY NOTES SECTION
when you make payment
Returns Policy
1. Customer satisfaction is our top goal. All products are quality checked. They are new and in good
condition when shipped to our customers. If product is defective or damage upon arrival, or wrong
product shipped, please keep in touch with us immediately. Returns accepted within 14 days of delivery date
and item must be in original new condition, not worn or altered in any way with attached tags & wrap.
Otherwise deal is final. Return shipping must be paid by buyer.
2. Please keep in touch with us first if you have anyproblems/questions/concerns. We will be happy to resolve
any issues you may have in a cordial and friendly manner.
3. We appreciate your Positive Feedback, and will do the same in return. PLEASE DO NOT leave
negative feedback without first communication with us. Please allow max 24 HOURS for us to respond
About Feedback
We maintain high standards of excellence and strive for 100% customer satisfaction! Feedback is
very important to us. We request that you keep in touch with us immediately BEFORE you give us neutral or
negative feedback, so that we can satisfactorily address your concerns.It is impossible to address
issues if we do not know about them!